Most fiber optic cables require multiple OTDR measurements by using different parameters to completely and accurately characterize their property ties. These types of tests can take more time than is acceptable during a network emergency or a lengthy commissioning process. When troubleshooting the close-range resolution versus long-range visibility, several sets of waveforms must be acquired by using different OTDR settings as often as necessary. After completing the first scan by using a short-duration optical pulse, the next scan will use a longer-duration optical pulse to provide additional optical power to test further along the optical fiber.
Newer OTDR's incorporate built-in testing programs that automatically characterize the fiber optics in a sequential manner, starting from the instrument-to-fiber connection and working outward. Such programs automatically determine which parameters need to change, based on criteria like signal-to-noise-ratio, length, total loss and elapsed time. They may also increase the number of averages, change the filtering, or adjust the gain of the detection circuitry in order to optimize the test results for each specific cable segment. Many other software enhancements have been introduced to the acquisition , analysis and archiving of fiber optical test data, making the OTDR an even more valuable asset for technicians to meet the challenges of supporting fiber optic cable plants.